MPI

10 KA CAPACITOR DISCHARGE MAGNETIZING UNIT

The complete units consists of :

Magnetizing units                                  the capacitors, controls, SCR                                                    switches etc. are housed in a  

                                                                container suitable for field                                                                                          operation. With a “ high / low”                                                                          switch a charge with 75V resp. 

                                                                55V can be selected.

Remote operating switch                       For triggering the discharge  

                                                                and the start of the charging 

                                                                operation.

Cables                                      4 pcs. 95 mm2 positive, 8 m long

                                                            4 pcs. 95 mm2negative,27m long

(4) Central Conductor                         1.5mlong sections of30mm O.D.                                                                       solid all with couplings

(5) Quick acting couplings                    2 pcs. To connect the shooting                                                              cables to the central conductor . 

 

TECHNICAL DATA

 

Capacity:                                                        Approx. 2 Farad

Power Input:                                      16A, 220 V, 50Hz

Output:                                                           10.000 A at 55 V

Charging times:                                               20 secs. Max. at 75 V

                                                                      14 secs. Max. at 55 V

 

Obtainable Amperes   In “ Low”                     In  “High” Position

 

With 1 Cable sets                      6.000 A                                7.500   A

With 2 Cable sets                      7.000 A                                9.000   A

With 3 Cable sets                      8.500 A                                10.500 A

With 4 Cable sets                     10.000 A                               12.000 A

 

For a safety reasons the discharge can only be triggered if the        pre - selected voltage has been attained and when the cable conductor circuit is closed.